Concentration limit for drinking water[a]
Pre-remediation concentration range at LLNL, Federal California March 1990- Discharge limit[b] for MCL MCL March 1991 treated water Constituent (ppb) (ppb) (ppb) (ppb)
PCE 5 5 <0.1-1,050 4TCE 5 5 <0.1-4,800 5
1,1-DCE 7 6 <0.5-370 5
cis-1,2-DCE 70 6 <0.5-24 5 (total 1,2-DCE)
trans-1,2-DCE 100 10 <0.5-1 5
1,1-DCA -- 5 <0.5-60 5
1,2-DCA 5 0.5 <0.1-190 5
Carbon tetrachloride 5 0.5 <0.1-91 5
Total THM[c] 100[c] 100[c] <0.5-270 5
Benzene 5 1.0 <0.1-4,600 0.7
Ethyl benzene 700 680 <0.2-610 5
Toluene 1,000 -- <0.5-4,200 5
Xylenes (total) 10,000 1,750[d] <0.5-3,700 5
Ethylene dibromide 0.05 0.02 <0.1-51 0.02
Total VOCs -- -- up to 5,808 5
Chromium+3 50(total Cr)[e] 50 (total Cr) <5-150 (total Cr) 50 (total Cr)
Chromium+6 50(total Cr)[e] 50 (total Cr) <10-140 11
Lead 15[f] 50 <2-10 5.6
Tritium[g] 20,000 pCi/L 20,000 pCi/L <200-33,100 [h]
| Contact Webmaster | LLNL Disclaimers | Rev. 6/2/97 |
|
||||
| Lawrence Livermore National
Laboratory 7000 East Avenue • Livermore, CA 94550 |
Operated by Lawrence Livermore National Security, LLC, for the Department of Energy's National Nuclear Security Administration | |||